X Series Manhole Boxes
X-Series Manhole Boxes
Pinnacle’s X-Series Manhole Boxes offer secure protection for workers during manhole excavation and maintenance. Made from heavy-duty steel, these boxes prevent cave-ins and provide stability in unstable soil. Perfect for utility and underground projects, they ensure a safe working environment, safeguarding personnel from potential hazards in challenging conditions.
*Images may feature optional components. Variations between the images and the actual equipment do exist, primarily with appurtenance locations, sizes, and quantities.
Model Number | Tare Weight | Pipe Clearance | Shield PSF | C-60 |
---|---|---|---|---|
PMXMH4-408 | 3500 | 15.25″ | 2525 | 42 |
PMXMH4-410 | 3900 | 15.25″ | 2275 | 38 |
PMXMH4-412 | 4400 | 15.25″ | 3415 | 57 |
PMXMH4-808 | 5200 | 63″ | 1325 | 22 |
PMXMH4-810 | 5700 | 63″ | 1325 | 22 |
PMXMH4-812 | 6100 | 63″ | 1395 | 23 |
Tappered Dog Doors Standard
Each of our steel manhole boxes comes with professional engineer certified and stamped tabulated data, which meets the OHSA 1926 Sub Part P Excavations standards
Frequently Asked Questions
- Determine Manhole Correct Size
- Installation Instructions
Determine Correct Size
To determine the right size of manhole box for your job answer the questions below.
Review the tables and information which accompany our specific products.
Always refer to manufacturer’s serialized specific tabulated data and all applicable safety standards prior to each use.
What kind of job is it?
Sewer, repair, water main, manhole, pump station, bore pit, etc.
Depth of cut?
Soil conditions?
B-soils (45 lbs per foot of pressure)
C-60 soils (60 lbs per foot of pressure)
C-80 soils (80 lbs per foot of pressure)
Determine Spreader Length
If working with pipe, what is the outside diameter of the pipe?
Pinnacle recommends that the manhole box to be at least 12” wider than the pipe.
Determine Trench Shield Length
If working with pipe, what is the length of the pipe sections?
Pinnacle recommends that the manhole box be 2’ – 4’ longer than the pipe.
Determine Maximum Weight of Manhole Box System
Determine the working operation weight of excavator being used at job site and divide it by 5. This number would provide you with the maximum weight you excavator can handle.
When selecting box size the weight should include the spreaders.
Installation Instructions
Step 1 Lay wall A of Manhole box flat on the ground with the collars facing up as shown | Step 2 Place each spreader on the collar one at a time as shown and insert pin and place keeper, make sure pin keeper in facing towards the bottom of manhole as shown |
---|---|
Step 3 Take wall B place over the top of the spreaders a shown and pin into place with keeper towards the bottom | Step 4 Take your rigging place on top lifting eyes inside as shown and left to stand |